  www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com MPU-600CD series input parameter conditions min. typ. max. units input voltage range universal 90 264 vac input frequency 47 63 hz input current, full load 90 vac 8.5 a inrush current, cold start 230 vac 70 a leakage current 264 vac 3.5 ma power factor correction meets en61000-3-2 class d input protection t10a/250v fuse inserted in primary input undervoltage protection under 80 vac (10 vac) unit shuts down; unit recovers over 90 vac output parameter conditions min. typ. max. units output voltage adjustment by trim pot, u-channel model only 5.0 % output regulation, see note 1 1.0 % hold time 115 vac, 75% load 16 msec ripple & noise (20 mhz), see note 2 see model selection guide overload protection foldback circuit, autorecovery 110 140 % over voltage protection >130% of rated output voltage. recycle ac input. over temperature protection autorecovery +105 +110 +115 oc temperature coef? cient 0.04 %/oc transient recovery time, see note 4 50% load change 2.5 ms transient response deviation 5.0 % overshoot/undershoot at turn on/off 5.0 % turn on delay 115 vac 2.0 s output short circuit continuous with autorecovery general parameter conditions min. typ. max. units isolation voltage, see note 5 input - output 3,000 vac input - fg (frame ground) 1,500 primary - core 1,500 switching frequency fixed 28 khz environmental parameter conditions min. typ. max. units operating temperature range ambient 0 +25 +50 oc storage temperature range -20 +80 oc cooling see model selection guide operating humidity rh, non-condensing 90 % emi characteristics parameter standard criteria level radiated emissions en 55022 b conducted emissions en 55022 b esd en 61000-4-2 a 4 kv contact rs en 61000-4-3 a 3v/m eft en 61000-4-4 a 1 kv surge en 61000-4-5 a 1 kv (l-l), 2 kv (l-g) cs en 61000-4-6 a 3v/rms pfm en 61000-4-8 a 1a/m voltage dips en 61000-4-11 a >95% 10 ms, 30% 500 ms b >95%, 500 ms reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 30oc, gnd benign 100 khours safety standards ul 60950, en 60950 vibration sinusoidal 5~50 hz, acceleration 7.35 m/s 2 on x, y & z axis electrical speci cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. key features: compact 600w supply pfc to en 61000-3-2 ? en 60950 approved (ul) ce certi ed fcc class b emissions universal ac input 3 packaging options 900w peak power dual output 600w power factor corrected ac/dc power supplies
www.micropowerdirect.com micropower direct ? 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com model selection guide notes: 1. output regulation includes line & load. 2. ripple & noise is measured from 10 hz to 20 mhz. connection to the unit is made with a 0.1 ? ceramic capacitor & a 22 ? electrolytic capacitor connected in parallel. 3. a 1% minimum load is required to maintain regulation & ripple speci cations. 4. transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 5. isolation speci cations are production hi-pot tested for 3 seconds. 6. ef ciency is measured with a 115 vac input and full load. 7. output power is given for the factory preset voltage. the maximum continuous output power level is 600w with 25 cfm air ow. all models provide a peak power level of 900w for a maximum duration of 500 s. for more information, contact the factory. 8. each unit includes an input fuse (250v/10a). since this fuse is not eld replaceable, it is recom- mended that an external fuse of the same size be used on the input of the power supply for protection. 9. the fan drive output (at connector cn4) provides 12v/300 ma to drive an external fan. model number some models may require a minimum order quantity. contact the factory for details at: sales@micropowerdirect.com pin function 1 field ground 2 field ground 3 missing 4 ac-line 5 ac-line 6 missing 7 ac-neutral connections input connector (cn1): terminal block: howder hd-121-3p: m3.5 screws 3 terminals, 9.5 mm centers output connector (cn2): terminal block: howder hd-121-6p: m3.5 screws 6 terminals, 9.5 mm centers logic signal connector (cn3): mating part no: jst xhp-3 or equivalent (chyao shiunn js-1001-03) fan driver connector (cn4): mating part no: jst xhp-2 or equivalent (chyao shiunn js-2001-2) input connector (cn1): molex mating part no: molex 09-50-3071 or equivalent (7 pins, 2 removed) pin function 1 field ground 2 ac-line 3 ac neutral output connector (cn2): molex mating part no: molex 09-50-3141 or equivalent pin function 1 +v1 out 2 +v1 out 3+v out 4-v out 5 +v2 out 6 +v2 out pin function 1 +v1 out 2 +v1 out 3 +v1 out 4 +v1 out 5 +v1 out 6-v out 7-v out 8-v out 9-v out 10 -v out 11 -v out 12 +v2 out 13 +v2 out 14 +v2 out pin function 1 remote on/off 2 common 3 power good pin function 1 minus 2 plus input connector (cn1): iec320 or equivalent available on ?nd fan models only interface signals power supply on bi-color led is green for ?power on?; orange when protection enabled remote sense compensates for up to a 0.5v line drop power good signal goes ttl high 100 to 500 ms after regulation. goes low at least 1 ms before the loss of regulation. will sink 100 ma. remote on/off a ttl low signal inhibits the output. hiccup mode. model number output voltage factory output current with 25 cfm (max a) max. output power (w) regulation (note 3) ripple & noise (note 2) ef ciency (note 6) MPU-600CD-0512yyz v1 +5 vdc 50.00a 600 5.0% 1.0% 80% v2 +12 vdc 33.33a MPU-600CD-0524yyz v1 +5 vdc 50.00a 600 5.0% 1.0% 80% v2 +24 vdc 16.67a MPU-600CD-1224yyz v1 +12 vdc 33.33a 600 5.0% 1.0% 80% v2 +24 vdc 16.67a
micropower direct ? 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com www.micropowerdirect.com mechanical dimensions mechanical dimensions , top fan ??models notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.50) notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.50)
micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com www.micropowerdirect.com mechanical dimensions , end fan ??models notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.50)


▲Up To Search▲   

 
Price & Availability of MPU-600CD

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X